谷茂龍 王建國
摘 要:本文分析了寧河地震臺(tái)FHD-2B質(zhì)子磁力儀數(shù)據(jù)受干擾的變化特征,并對(duì)高壓直流供電、車輛影響等干擾因素進(jìn)行研究,以幫助工作人員識(shí)別和剔除干擾,以進(jìn)一步提高地磁觀測數(shù)據(jù)的準(zhǔn)確性。
關(guān)鍵詞:地磁;高壓直流供電;車輛干擾
中圖分類號(hào):P315.62 文獻(xiàn)標(biāo)識(shí)碼:A 文章編號(hào):1003-5168(2019)28-0138-03
The FHD-2B Proton Magnetometer of Ninghe Seismological
Station is Disturbed by the Observation Environment
GU Maolong WANG Jianguo
(Tianjin Earthquake Agency,Tianjin 300201)
Abstract: In this paper, the variation characteristics of the interference of FHD-2B proton magnetometer data at Ninghe seismic station were analyzed, and the interference factors such as high-voltage DC power supply and vehicle influence were studied to help the staff identify and eliminate the interference, so as to further improve the accuracy of geomagnetic observation data.
Keywords: geomagnetism;high voltage DC power supply;vehicle interference
FHD質(zhì)子磁力儀是江蘇地震局在“九五”期間研制的智能化分量質(zhì)子磁力儀,能連續(xù)測量和記錄地磁場的變化[1]。FHD-2B質(zhì)子磁力的觀測是一個(gè)長期的過程,觀測數(shù)據(jù)會(huì)受到各種因素的干擾,正確分辨自然觀測環(huán)境和人工等干擾因素的差異并進(jìn)行分析處理,對(duì)實(shí)踐應(yīng)用和地震預(yù)報(bào)具有重要意義。
1 儀器觀測條件
1.1 觀測環(huán)境
寧河地震臺(tái)位于寧河區(qū)大北澗沽鎮(zhèn)大北澗沽村西,距天津市區(qū)直線距離約52km,東距渤海灣25~30km,占地10 133m2,東面是馬路和田地,南面是幼兒園和暖氣片廠,西面是腳手架租賃廠,北面是中小學(xué)。2004—2005年實(shí)施寧河地震臺(tái)站優(yōu)化改造工程[2]。改造后的地磁觀測室,無論地磁場的水平梯度還是保溫性能,均達(dá)到區(qū)域地磁臺(tái)觀測規(guī)范的技術(shù)要求[3]。地磁房建在臺(tái)站東南角,距辦公用房約40m。寧河地震臺(tái)FHD-2B質(zhì)子磁力儀布設(shè)圖如圖1所示。
1.2 儀器簡介
FHD-2B質(zhì)子磁力儀是在FHD-1型質(zhì)子磁力儀的基礎(chǔ)上改進(jìn)研制而成,具有觀測精度高、智能化程度高、工作可靠性與穩(wěn)定性高等特點(diǎn)。寧河地震臺(tái)FHD-2B質(zhì)子磁力儀于2016年12月29日架設(shè)完畢并投入觀測,數(shù)據(jù)連續(xù)可靠。除線圈需要手動(dòng)調(diào)節(jié)外,F(xiàn)HD-2B質(zhì)子磁力儀實(shí)現(xiàn)了數(shù)字化、網(wǎng)絡(luò)化控制,用戶可以通過因特網(wǎng)瀏覽該儀器網(wǎng)頁,下載地磁觀測數(shù)據(jù),監(jiān)視儀器的運(yùn)行狀態(tài),對(duì)儀器進(jìn)行參數(shù)控制。
2 干擾分析
觀測環(huán)境是存在于臺(tái)站內(nèi)外的各種電磁干擾[4]。通過分析觀測資料可知,主要干擾來源于臺(tái)站外圍,如高壓直流輸電、車輛干擾。通過分析對(duì)比這些干擾因素,找出干擾的原因、特點(diǎn)和區(qū)別。
2.1 高壓直流輸電干擾
隨著我國經(jīng)濟(jì)的快速發(fā)展,高壓直流輸電線路的建設(shè)和運(yùn)行越來越多,當(dāng)高壓直流輸電線路出現(xiàn)故障,或者進(jìn)行線路測試檢修時(shí),會(huì)對(duì)一定范圍內(nèi)的地磁觀測造成很大干擾[5]。寧河地震臺(tái)半徑500km內(nèi)有3條高壓直流輸電線路,分別為錫泰線、扎青線和呼遼線。錫泰線位于寧河臺(tái)西側(cè),離臺(tái)站最短距離約60km;扎青線位于寧河臺(tái)西側(cè),離臺(tái)站最短距離約50km;呼遼線位于寧河臺(tái)東北側(cè),離臺(tái)站最短距離約480km。根據(jù)寧河臺(tái)FHD-2B觀測資料統(tǒng)計(jì),2018年共記錄到23d高壓直流輸電干擾,其中錫泰線干擾11d、扎青線11d、呼遼線1d。經(jīng)過對(duì)觀測數(shù)據(jù)進(jìn)行處理發(fā)現(xiàn),高壓直流輸電對(duì)垂直分量[Z]的影響較大,對(duì)磁偏角和水平分量影響較小;扎青線與錫泰線與臺(tái)站距離較近,干擾較多,而呼遼線距離較遠(yuǎn),干擾較少;距離越遠(yuǎn),干擾幅度越小。圖2、圖3和圖4是寧河地震臺(tái)質(zhì)子磁力儀原始和預(yù)處理數(shù)據(jù)對(duì)比。
2.2 車輛干擾
車輛干擾是鐵磁性物質(zhì)對(duì)地磁場干擾的一種,干擾類型主要包括:農(nóng)用車作業(yè)、基建施工、車輛駛?cè)胗^測區(qū)等。寧河地震臺(tái)通過網(wǎng)絡(luò)視頻監(jiān)控系統(tǒng)完成了對(duì)地磁房周邊環(huán)境的實(shí)時(shí)監(jiān)測,對(duì)比監(jiān)控畫面和數(shù)據(jù)變化確定干擾源和干擾時(shí)段。經(jīng)過對(duì)觀測數(shù)據(jù)進(jìn)行處理發(fā)現(xiàn),地磁房西南面140m處暖氣片廠大貨車和東面耕地農(nóng)用車干擾較大,會(huì)出現(xiàn)尖峰和臺(tái)階。因FHD-2B質(zhì)子磁力儀測量的是分鐘值,過路車輛偶爾會(huì)造成數(shù)據(jù)出現(xiàn)數(shù)個(gè)尖峰,處理數(shù)據(jù)時(shí)剔除突跳即可。圖5是寧河臺(tái)質(zhì)子磁力儀各分量原始數(shù)據(jù)。因東面30m處耕地農(nóng)用車干擾距離較近,磁偏角變幅為16.2′,水平分量變幅為146.3nT,總強(qiáng)度變幅為61.3nT。雖然數(shù)據(jù)曲線變形嚴(yán)重,但農(nóng)用車耕作時(shí)間較短,此類干擾又容易判別和處理,對(duì)長期觀測無明顯影響。
2018年5月發(fā)現(xiàn)西南140m處暖氣片廠大貨車頻繁出入和停留,嚴(yán)重影響觀測數(shù)據(jù)質(zhì)量。統(tǒng)計(jì)2018年全年受干擾天數(shù)有71d,其中6月干擾達(dá)29d,給值班人員的處理數(shù)據(jù)帶來很多麻煩。在處理數(shù)據(jù)時(shí)發(fā)現(xiàn),大貨車對(duì)水平分量和磁偏角干擾形態(tài)多為臺(tái)階,水平分量干擾幅度在2.0~12.0nT,磁偏角在0.2′~1.2′;貨車停放位置超出200m時(shí)磁偏角無明顯干擾;垂直分量影響較小,常表現(xiàn)為開始和結(jié)束時(shí)的幾個(gè)突跳。圖6是寧河臺(tái)質(zhì)子磁力儀各分量預(yù)處理數(shù)據(jù)和原始數(shù)據(jù)的差值。
在日常觀測中,常常會(huì)同時(shí)遇到多種干擾,如圖7所示。臺(tái)站工作人員需要根據(jù)數(shù)據(jù)的變化特征初步識(shí)別干擾類型,同時(shí)利用地磁臺(tái)網(wǎng)高壓直流輸電判別系統(tǒng)和中國地震前兆數(shù)據(jù)處理系統(tǒng)與附近臺(tái)站對(duì)比確認(rèn)干擾源。一般情況下,水平分量變化幅度大于垂直分量屬于高壓直流輸電干擾;垂直分量變化幅度大于水平分量屬于車輛干擾。當(dāng)然,影響地磁觀測數(shù)據(jù)的因素還有很多,比如太陽活動(dòng)、觀測設(shè)施和觀測儀器自身因素等[6]。因此,工作人員需要通過科學(xué)的方法,對(duì)數(shù)據(jù)質(zhì)量中關(guān)鍵性問題予以檢驗(yàn)、控制,以確保觀測數(shù)據(jù)質(zhì)量。
3 結(jié)語
隨著中國經(jīng)濟(jì)全面快速發(fā)展,地震觀測環(huán)境日益惡化,觀測數(shù)據(jù)也出現(xiàn)了各種異常。面對(duì)這種情況,有效識(shí)別干擾和確認(rèn)前兆異常信息具有重要意義。本文分析了出現(xiàn)的異常與干擾源成因、干擾幅度與干擾源位置的關(guān)系和不同干擾之間的區(qū)別,識(shí)別和剔除干擾。
根據(jù)以往觀測經(jīng)驗(yàn),F(xiàn)HD磁房與車輛相距200m以上,一般不會(huì)對(duì)數(shù)據(jù)曲線造成干擾。臺(tái)站工作人員若發(fā)現(xiàn)范圍內(nèi)存在干擾車輛,可通過人為干預(yù)的辦法消除干擾。同時(shí),可在臺(tái)站圍墻外安裝地磁環(huán)境保護(hù)警示牌,提高村民意識(shí),達(dá)到保護(hù)地磁環(huán)境的效果。
參考文獻(xiàn):
[1]夏忠,馮志生,稽才建,等.FHD-1型質(zhì)子磁力儀的改進(jìn)與完善[J].地震學(xué)刊,2002(2):28-31.
[2]天津市第十二屆政協(xié)人口資源環(huán)境和城市建設(shè)委員會(huì),天津市地震局.天津市防震減災(zāi)回顧與展望[M].天津市第十二屆政協(xié)人口資源環(huán)境和城市建設(shè)委員會(huì),2012.
[3]刑力.地磁觀測FHD儀器房建設(shè)中的磁性控制[J].河南科技,2015(2):103-105.
[4]中國地震局監(jiān)測預(yù)報(bào)司.地震電磁學(xué)理論基礎(chǔ)與觀測技術(shù)[M].地震出版社,2010.
[5]陳健,張秀霞,劉江斌,等.江蘇地磁觀測受高壓直流輸電干擾現(xiàn)狀及預(yù)處理[J].地震學(xué)刊,2016(4):27-30.
[6]全建軍,夏忠,張凱,等.永安地磁臺(tái)FHD-2B質(zhì)子磁力儀觀測數(shù)據(jù)干擾分析[J].地震地磁觀測與研究,2015(1):120-125.